The authors would like to thank the Spanish Ministry of Economy and Competitiveness for partially funding this work under projects DPI2015-71219-C2-2-R and DPI2015-66478-C2-1-R, and they would like to acknowledge the support of the Chilean Research Council (CONICYT), under the project Fondecyt 11160115.

Anàlisi d'autories institucional

Albarracin, RicardoAutor (correspondència)

Compartir

7 d’octubre de 2024
Publicacions
>
Article
No

Partial discharges: keys for condition monitoring and diagnosis of power transformers

Publicat a:Power Transformer Condition Monitoring And Diagnosis: Concepts And Challenges. 104 39-85 - 2018-01-01 104(), DOI: http://dx.doi.org/10.1049/https://doi.org/10.1049/PBPO104E_ch2

Autors: Albarracin, Ricardo; Robles, Guillermo; Alfredo Ardila-Rey, Jorge; Cavallini, Andrea; Passaglia, Renzo

Afiliacions

CESI SpA Milan, Milan, Italy - Autor o coautor
Univ Bologna, Dept Elect Elect & Informat Engn Guglielmo Marcon, Bologna, Italy - Autor o coautor
Univ Carlos III Madrid, Dept Elect Engn, Madrid, Spain - Autor o coautor
Univ Politecn Madrid, Escuela Tecn Super Ingn & Diseno Ind ETSIDI, Dept Elect Elect Automat Engn & Appl Phys, Madrid, Spain - Autor o coautor
Univ Tecn Federico Santa Maria, Dept Elect Engn, Santiago, Chile - Autor o coautor
Veure més

Resum

The combination of thermal and electrical stress, in conjunction with the synergic effects of moisture in the insulation, might dramatically reduce the lifetime of a power transformer, which is roughly estimated to be 40 years if properly maintained, meaning that many transformers do not experience any failures before being dismantled. Mechanical stresses during short-circuits can also play a role leading, in the worst case, to the radial buckling of the winding and damage of the connection cables at the bushing terminations. A number of these factors can, in the course of time, give rise to partial discharge (PD) phenomena which can be a cause of failure or a symptom of degradation. PD measurements can be carried out conventionally, following the standards IEC 60270 and IEC 60076. Alternative methods, such as those presented in the IEC TS 62478 standard based on acoustic or ultra-high frequency sensors, have been proposed and might offer better sensitivity, particularly for monitoring purposes, and the capability to locate the PD sources. For all these methods, identification of the PD source is a key to achieve a correct course of action (run, repair and replace).

Paraules clau

BucklingBushing terminationsClassificationCondition monitoringConnection cablesDielectric breakdown and dischargesElectrical stressIdentificationIec 60076 standardIec 60270 standardIec standardsIec ts 62478 standardInsulationInsulation and insulating coatingsLocalizatioMechanical stressesNeural-networkPartial discharge measurementPartial discharge phenomenaPattern-recognitionPd detectionPd measurementsPd sourcePower transformer diagnosisPower transformer insulationRadial bucklingRogowski coilShort-circuitsSource discriminationSynergic effectsThermal stressThermal stressesTransformer windingsTransformers and reactorsUhf sensorsUltrahigh frequency sensorsWinding

Indicis de qualitat

Impacte bibliomètric. Anàlisi de la contribució i canal de difusió

Independentment de l'impacte esperat determinat pel canal de difusió, és important destacar l'impacte real observat de la pròpia aportació.

Segons les diferents agències d'indexació, el nombre de citacions acumulades per aquesta publicació fins a la data 2025-09-19:

  • Google Scholar: 11
  • WoS: 8
  • Scopus: 11

Anàlisi del lideratge dels autors institucionals

Aquest treball s'ha realitzat amb col·laboració internacional, concretament amb investigadors de: Chile; Italy.

Hi ha un lideratge significatiu, ja que alguns dels autors pertanyents a la institució apareixen com a primer o últim signant, es pot apreciar en el detall: Primer Autor (ALBARRACIN SANCHEZ, RICARDO) .

l'autor responsable d'establir les tasques de correspondència ha estat ALBARRACIN SANCHEZ, RICARDO.