{rfName}
Op

Indexado en

Licencia y uso

Citaciones

Altmetrics

Análisis de autorías institucional

Sauvan P.Autor o Coautor

Compartir

Publicaciones
>
Artículo

Optimizing Radiation Shielding for Fusion Maintenance Facilities: Insights From a Comprehensive Analysis of ITER Hot Cell

Publicado en:International Journal Of Energy Research. 2025 (1): - 2025-01-01 2025(1), DOI: 10.1155/er/9222155

Autores: Martínez-Albertos P; Sauvan P; Catalán JP; Belotti M; Javier F; Germa J; Le Tonqueze Y; Dammann A; Juárez R

Afiliaciones

TECF3IR Group; Universidad Nacional de Educación a Distancia (UNED); C/Juan del Rosal 12; Madrid; 28040; Spain - Autor o Coautor
TECF3IR Group; Universidad Nacional de Educación a Distancia (UNED); C/Juan del Rosal 12; Madrid; 28040; Spain; Hexana; Europarc de Pichaury; 1330 Rue Jean-René Guillibert Gautier de la Lauziére; Aix-en-Provence; 13290; France - Autor o Coautor
TECF3IR Group; Universidad Nacional de Educación a Distancia (UNED); C/Juan del Rosal 12; Madrid; 28040; Spain; Newcleo; Tour Silex; 9 rue des Cuirassiers; Lyon; 69003; France - Autor o Coautor

Resumen

One of the primary goals of the ITER project is to demonstrate the safety characteristics of a fusion device, particularly in terms of radiation management. Radiation protection during maintenance periods is of special concern, as personnel performing maintenance-like activities will be exposed to delayed gamma fields from numerous and complex radioactive components. Ensuring a safe and equipped environment for such activities is the objective of the ITER hot cell. This facility requires extensive design optimization, balancing spatial and temporal availability constraints, radiation protection, and cost-effectiveness. In this paper, we present a comprehensive assessment of ITER hot cell’s radiation environment to support its efficient design and safe operation. The study evaluates the shielding efficiency of the conceptual design layout from 2021, providing meaningful insights for layout improvement. We show that substantial amounts of concrete (~2900 m3) could be saved from the currently evolving design while respecting radiological requirements. The evaluation of the occupational radiation exposure (ORE) associated with hot cell maintenance activities resulted in 179 man·mSv·year−1, which represents a significant fraction (36%) of the project’s annual budget. This highlights the importance of integrating shielding analysis, accounting for personnel radiation exposure, even in early design phases, to support the optimization of the maintenance plan according to safety requirements. Copyright © 2025 Pablo Martínez-Albertos et al. International Journal of Energy Research published by John Wiley & Sons Ltd.

Palabras clave

Budget controlComprehensive analysisElectromagnetic shieldingFusion devicesGamma raysHeat radiationHot cellIterIter projectMaintenance facilityOccupational radiation exposureRadiationRadiation exposureRadiation managementReactor shieldingShielding analysis

Indicios de calidad

Impacto bibliométrico. Análisis de la aportación y canal de difusión

El trabajo ha sido publicado en la revista International Journal Of Energy Research debido a la progresión y el buen impacto que ha alcanzado en los últimos años, según la agencia WoS (JCR), se ha convertido en una referencia en su campo. En el año de publicación del trabajo, 2025, se encontraba en la posición 83/171, consiguiendo con ello situarse como revista Q1 (Primer Cuartil), en la categoría Energy & Fuels.